Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Hand Surg Asian Pac Vol ; 28(3): 415-420, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37173139

RESUMEN

Surgical principles in sarcoma are a wide resection, including surrounding tissues and maximisation of the function of the affected limb. Rotator cuff muscles are biomechanically important structures acting as a force couple in movement of the shoulder joint. Thus, conjoined tendons are essential for motion capability in absence of the supraspinatus muscle. This article reports a case of a large undifferentiated pleomorphic sarcoma (UPS) at the suprascapular fossa in a 78-year-old man. After diagnosis of sarcoma, he underwent wide, en-bloc excision preserving conjoined tendons of rotator cuff muscles and low-dose radiation therapy for surveillance of local recurrence. All dissection was performed to avoid contaminating the tumour and involved the whole supraspinatus except the conjoined tendons. We report a case of UPS at the suprascapular fossa, which showed a good result after a wide resection preserving conjoined tendons of rotator cuff muscles. Level of Evidence: Level V (Therapeutic).


Asunto(s)
Sarcoma , Neoplasias de los Tejidos Blandos , Masculino , Humanos , Anciano , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Sarcoma/cirugía , Disección , Movimiento (Física) , Movimiento , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Neoplasias de los Tejidos Blandos/cirugía
2.
Arthrosc Tech ; 11(5): e881-e888, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35646577

RESUMEN

Varus alignment of the knee joint (varus >5°) is known as a poor prognostic factor for medial meniscus root repair, and alignment correction is recommended in patients with varus deformity and medial meniscus root tears. However, simultaneous medial meniscus pull-out repair and high tibial osteotomy are technically demanding procedures due to the long surgical time, poor visualization, and breaking of the pull-out sutures during high tibial osteotomy procedures. In the present Technical Note, we will introduce a surgical method to perform 2 procedures simultaneously without technical difficulty. The main surgical techniques are as follows. (1) Release the superficial medial collateral ligament before arthroscopic medial meniscus pull-out repair, which secures sufficient working space and visualization. Therefore, the operation time could also be reduced by performing the arthroscopic procedure with the anterior portal. (2) Protect the pull-out sutures with an ENDOBUTTON reamer, which prevents pull-out sutures from breaking during the high tibial osteotomy procedure.

3.
Geriatr Orthop Surg Rehabil ; 13: 21514593221074179, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35299833

RESUMEN

Hardware removal in a healed intertrochanteric fracture in elderly, which is not a routine procedure, should be needed in the case of irritable hardware. The reports of refracture after hardware removal can be seen as sparse in current literature, which are focused to secondary femoral neck fracture after removal of the lag screw or blade. We experienced a case of the intertrochanteric refracture and varus collapse after the PFNA removal in a healed fracture, treated with valgus trochanteric osteotomy and angled blade plate fixation. The PFNA is an innovative device for the treatment of the trochanteric fracture; however, the complications after removal never end. Therefore, the removal from healed fracture in elderly who have osteoporosis should not be recommended unless intractable pain had persisted.

4.
Acta Radiol ; 61(11): 1545-1552, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32077302

RESUMEN

BACKGROUND: Coronal and sagittal views of magnetic resonance imaging (MRI) were used to determine rotator cuff tear size and fatty infiltration, but these images were not enough to identify the tear shape. PURPOSE: To correlate the preoperative axial MRI views and arthroscopic surgical findings to identify the two-dimensional shapes in rotator cuff tears. MATERIAL AND METHODS: This study included 166 patients who underwent arthroscopic repair between 2015 and 2018. Preoperative coronal, sagittal, and axial MRI views were evaluated for tear size and geographic configuration in axial sections, and the length and the width were measured and were matched with arthroscopic surgical views by lateral portals. RESULTS: The agreement of axial MRI views with the arthroscopic view was 88.0% in crescent, 97.2% in longitudinal, 78.6% in massive, and 100% in rotator cuff tear arthropathy. The mean agreement rate of axial MRI views with arthroscopic view was 81.9%. Mean mediolateral and anteroposterior tear sizes on axial MRI were 16.68 mm and 19.33 mm, respectively. Mean mediolateral and anteroposterior tear sizes by arthroscopic view were 21.49 mm and 21.04 mm, respectively. Tear sizes by MRI axial images were 71.3% of arthroscopic view. SST/IST degenerative changes were noted in most patients with massive tears and rotator cuff arthropathy (P = 0.001). CONCLUSION: Rotator cuff tear shape on preoperative axial MRI view had close agreement (81.9%) with arthroscopic findings by lateral portal, and tear size by preoperative axial MRI views was 71.3% of that of arthroscopic view. Axial MRI views helped to predict the geometric tear shape of rotator cuff tears.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Cuidados Preoperatorios/métodos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía
5.
Injury ; 48(10): 2074-2079, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28764917

RESUMEN

OBJECTIVES: The purpose of this study was to predict the possibility of transverse iliosacral (TIS) screw fixation into the first sacral segment (S1) and introduce practical anatomical variables using conventional computed tomography (CT) scans. MATERIALS AND METHODS: A total of 82 cadaveric sacra (42 males and 40 females) were used for continuous 1.0-mm slice CT scans, which were imported into Mimics® software to produce a three-dimensional pelvis model. The anterior height (BH) and superior width (BW) of the elevated sacral segment was measured, followed by verification of the safe zone (SZS1 and SZS2) in a true lateral view. Their vertical (VDS1 and VDS2) and horizontal (HDS1 and HDS2) distances were measured. VDS1 less than 7mm was classified as impossible sacrum, since the transverse fixation of 7.0 mm-sized IS screw could not be done safely. RESULTS: Fourteen models (16.7%; six females, eight males) were assigned as the impossible sacrum. There was no statistical significance regarding gender (p=0.626) and height (p=0.419). The average values were as follows: BW, 31.4mm (SD 2.9); BH, 16.7mm (SD 6.8); VDS1, 13.4mm (SD 6.1); HDS1, 22.5mm (SD 4.5); SZS1, 239.5mm2 (SD 137.1); VDS2, 15.5mm (SD 3.0); HDS2, 18.3mm (SD 2.9); and SZS2, 221.1mm2 (SD 68.5). Logistic regression analysis identified BH (p=0.001) and HDS1 (p=0.02) as the only statistically significant variables to predict the possibility. Receiver operating characteristic curve analysis established a cut-off value for BH and HDS1 of impossible sacrum of 20.6mm and 18.6mm, respectively. CONCLUSION: BH and HDS1 could be used to predict the possibility of TIS screw fixation. If the BH exceeds 20.6mm or HDS1 is less than 18.6mm, TIS screw fixation for S1 should not be undertaken because of narrowed SZ.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas , Fracturas Óseas/cirugía , Ilion/cirugía , Sacro/cirugía , Cirugía Asistida por Computador , Adulto , Cadáver , Femenino , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/diagnóstico por imagen , Humanos , Ilion/anatomía & histología , Ilion/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Valores de Referencia , Reproducibilidad de los Resultados , Sacro/anatomía & histología , Sacro/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto Joven
6.
J Bone Metab ; 23(1): 45-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26981521

RESUMEN

Insufficiency fracture of the calcaneus is a rare entity. In the absence of trauma, evaluating a painful ankle in an elderly patient can be difficult and also it might be overlook the insufficiency fracture. We experienced a case of insufficiency calcaneus fracture that occurred after ipsilateral total knee arthroplasty. Here, we report our case with a review of literatures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...